The BCU 370 burner control unit controls, ignites and moni- tors industrial forced draught burners of unlimited capacity in intermittent or continuous operation.

Burner control unit BCU 370 For modulating, forced draught burners for gas of unlimited capacity in intermittent or continuous operation Control of blower and butterfly valve Space-saving thanks to incorporated ignition transformer Simple system set-up thanks to optional tightness control Easy start-up and maintenance thanks to Manual operating mode Enhanced availability and simplified.

Manual/Automatic mode and display of operating and fault statuses in a com-pact metal housing. Application The burner control units BCU 480 con-trol, ignite and monitor gas burners for intermittent or continuous operation. As a result of their fully electronic design they react quickly to various process requirements and are therefore suit-able for frequent cycling operation.

  1. The program status, the unit parameters and the level of the flame signal can be read directly from the BCU. An integrated Manual mode allows manual start of the burner and setting of the butterfly valve position independently of the central control system.

  2. www.kromschroeder.com The burner control unit BCU 370 monitors the gas and air pressure. Manual mode allows manual start of the burner and setting.

  3. BCU 370 Burner Control Unit For modulating, forced draught burners for gas of unlimited capacity in intermittent or continuous operation Control of fan and butterfly valve Simple system set-up thanks to optional tightness control and integrated ignition unit Easy start-up and maintenance thanks.

The BCU 370 burner control unit controls, ignites and monitors industrial forced draught burners of unlimited capacity in intermittent or continuous operation.

Burner control unit BCU 370 Product brochure · GB 6.1.3.2 Edition 12.05 • For modulating, forced draught burners for gas of unlimited capacity in intermittent or continuous operation • Control of fan and butterfly valve • Simple system set-up thanks to optional tightness control and integrated ignition unit • Easy start-up and maintenance thanks to Manual operating mode • Enhanced.

Kromschroder's BCU 370 burner control unit is designed to control, ignite, and monitor industrial forced draught burners in intermittent or continuous operation. It can be used both for burners that are ignited directly and those that are lit with a pilot burner.

Kromschroder's BCU 370 burner control is designed to control, ignite, and monitor forced The BCU 370 activates the blower, positions the butterfly valve to the pre-purging and 2.7MB; Kromschroder BCU 370 Burner Control Unit Manual .